Salon freshaire 1 to 4 station kit

Salon freshaire 1 to 4 station kit

Beware of others, code requirement requires toxic fumes are exhausted to the outside. Every workspace source must have an airflow damper control to achieve a balance of 50 cubic feet per minute. Air going out must be regulated to come back in fresh. Almost all systems, nail tables, and pedicures available today do not do solve the toxic fume issue by offering an intake and a pipe or a filter. You will waste money and fail passing inspection. Design X offers a complete solution, with proper air regulation per health code requirement. The patented Salon FreshAire ventilator unit for up to 4 work sources connects to any of our nail tables and pedicure spas providing high-efficiency toxic fume exhaust and fresh air recovery by applying economical temperature acclimation during the fresh air recovery in a compact, affordable package for nail and hair salons. Each FreshAire ventilator balances exhaust and fresh airstreams while moderating temperature extremes and humidity both in summer and winter in nail and hair salons. The systems purpose is to be health code compliant by removing toxic fumes from all nail salon chemical pollutants at the work source. City codes and landlords are now requiring nail salons to provide a way to capture and exhaust harmful fumes and supply back fresh outdoor air.

CODE COMPLIANT:  The patented system provides source capture at each station capable of exhausting 50CFM directly outdoors in accordance with table 403.3.1.1 (2017 FBC Mechanical Code) note b and h. The mechanical code requires that a ventilation system be air balanced.  That means the amount of fresh air coming in shall equal the amount of air that is being exhausted outside.  Our system provides code compliance for fresh air and toxic source capture in one, small, energy efficient package. The FreshAire unit supplies makeup air to keep the ventilation in balance all while being whisper quiet. The system pre-conditions the incoming fresh air using the temperature and humidity of the exhaust air without mixing with fresh air.  For more than 4 worksources more FreshAire units would be needed.

FreshAire unit weighs approximately 65lbs and can be placed in a back room or hung from the deck above and doesn’t require upgrades to electrical service or modifications to existing HVAC systems.

Size:

  • Width: 31” (787 mm)
  • Height: 21-3/4” (552 mm)
  • Depth: 17-1/16” (433 mm)

ELECTRICAL REQUIREMENTS

  • 120 VAC, 60 Hz, 2.1 A, 252 W
  • Cord Set: 48” (1219 mm) with ground
More